Innovative and customer-oriented solutions Alpha Maintenance Systems is the Belgian subsidiary of the WearCheck International Group, with locations in Europe, North America, the UK, South Africa and Asia. Its highly qualified employees apply t...
https://alphams.eu/nl/labo/ -
News
https://alphams.eu/nl/nieuws/ -
Analyses
Analyses
https://alphams.eu/nl/analyses/ -
Products
https://alphams.eu/nl/producten/ -
Programs
https://alphams.eu/nl/programmas/ -
Contact
Contact Alpha Maintenance Systems Alpha Maintenance Systems BVBA Bergensesteenweg 713 1600 Sint-Pieters-Leeuw T +32 2 365 02 29 F +32 2 361 34 58 labo@alphams...
https://alphams.eu/nl/contact/ -
Sampling
The best sampling method Two objectives when taking a correct sample: 1. Maximum density and minimum disturbance of the data 2. The correct frequency and always the same sampling point Useful tips for correct sampling: • Alw...
https://alphams.eu/nl/labo/monstername/ -
Vacancies
There are currently no vacancies.
https://alphams.eu/nl/labo/vacatures/ -
Model reports
https://alphams.eu/nl/labo/rapportvoorbeelden/ -
Sitemap
https://alphams.eu/nl//sitemap/ -
Search results
https://alphams.eu/nl//zoeken/ -
My Wearcheck
Send in your sampling form online
https://alphams.eu/nl//mijn-wearcheck/ -
Sampling Material
https://alphams.eu/nl/producten/monsternamemateriaal/ -
Brochures
https://alphams.eu/nl/brochures/ -
Saipem
https://alphams.eu/saipem/ -
Sample registration
How do you request an analysis of an oil monster? Step 1: Apply for a sampling set To send your oil samples in a correct manner to AlphaMS, you can request a sampling set. There are two standard sets available for analysis of 6 or 100 samp...
https://alphams.eu/nl/labo/monsterregistratie/ -
Cookie policy
Cookie policy During a visit to our website, cookies (small text files) can be placed on the hard disk of the visitor's computer. This with the sole aim to better tailor the site to the needs of the visitor. Cookies are never used to check...
https://alphams.eu/nl//cookie-policy/ -
Kroon-Oil
Submit your sampling form online
https://alphams.eu/kroon-oil/ -
Privacy policy
Privacy Policy Your privacy is very important to us. This means that we store your data securely and make sure that they are properly protected. We will also inform you about what we do with your data when we respectfully use it to provide you...
https://alphams.eu/nl//privacy-policy/ -
General conditions of sale
Art. 1 Acceptance of the general sales terms and conditions These terms and conditions apply to all sales agreements between Alpha Maintenance Systems bv and its customers, and to all quotes from Alpha Maintenance Systems bv, except in so far as...
https://alphams.eu/nl/labo/verkoopvoorwaarden/ -
Vacancy Sales Engineer
https://alphams.eu/salesengineer/ -
Oxidation and degradation of a lubricant
Oxidation of a lubricant is a chemical process that changes a lubricant and makes it lose its chemical and physical properties. A quality lubricant contains antioxidant...
https://alphams.euen/news/?news=16 -
Mikrocount Combi
With the microbiological MIKROCOUNT test, you can verify the concentrations of bacterial categories in a simple way and quickly restore the quality of your liquids. This wi...
https://alphams.eu/en/products/sampling/?product=5 -
Sampling box (6 or 100 units)
Our sampling boxes contain: - 6 or 100 separately packaged sampling bottles (100 ml) - 6 or 100 forms with unique barcodes - 6 or 100 pre-addressed envelopes
https://alphams.eu/en/products/sampling/?product=7 -
Fluid sampler
The Fluid Sampler is a strong and professional pump, specifically developed for sampling water, oil and other liquids.
https://alphams.eu/en/products/sampling/?product=8 -
Oil Safe
Oil Safe protects lubricants against contamination. The special sealable nozzles keep dirt from intruding. Airborne particles will not land in the lubricant and consequentl...
https://alphams.eu/en/products/sampling/?product=9 -
Fluid sampling tube
De monsternameslang is een cilindervormige tube met een lengte van 1,5m die in combinatie met de Fluid Sampler kan worden gebruikt om gemakkelijk een oliemonster te nemen v...
https://alphams.eu/en/products/sampling/?product=19 -
% TWO-STROKE OIL IN PETROL
The exact proportion of oil in petrol is determined following extraction of the solvent (petrol), after which the oil fraction is weighed and converted to a concentration i...
https://alphams.euen/analyses/#1 -
AEROBIC BACTERIA/MOULDS/YEASTS
The sample is spread across the microcount Combi growth medium and incubated in the incubator at 37°C. After 24 hours the number of aerobic bacteria is read in quantity...
https://alphams.euen/analyses/#2 -
BASE NUMBER (BN/TBN)
The BN value (or TBN value) of an engine oil represents the reserve alkalinity of an engine oil, i.e. the capacity of the oil to be able to neutralise acids in the oil. The...
https://alphams.euen/analyses/#3 -
RESERVE ALKALINITY
The reserve alkalinity of an antifreeze is measured by way of titration of the bases by an acid, hydrogen chloride, until all acids are neutralised. This is called the equi...
https://alphams.euen/analyses/#6 -
ANAEROBIC BACTERIA
The anaerobic bacteria in a sample are measured by placing the sample in the bottom of a closed container with a growth medium and to incubate this for 48 hours at 37°C...
https://alphams.euen/analyses/#7 -
ANILINE POINT
A portion of oil is mixed with an equal amount of aniline. This is heated until the aniline and oil form a single phase when mixed. The mixture is then cooled to the moment...
https://alphams.euen/analyses/#8 -
ASH CONTENT
The ashes are measured by burning the organic components of an oil or lubricant sample at a high temperature, as a result of which only ash remains which consists of metal ...
https://alphams.euen/analyses/#9 -
FIRE POINT - COC - Cleveland Open Cup
The flash point of an oil is the temperature at which the oil releases so many inflammable substances that the oil, in the presence of a flame and air, inflames and continu...
https://alphams.euen/analyses/#10 -
FUEL DILUTION BY MEANS OF GAS CHROMATOGRAPHY
By means of gas chromatography, molecules are separated from each other according to size at a high temperature. With this method it is possible to determine the proportion...
https://alphams.euen/analyses/#11 -
CORROSION TEST - FORD TEST - Cast Iron
On a paper filter 2 grams of standardised iron filings are weighed. 2 ml of the fluid to be examined is poured onto this. After 24 hours the iron filings are rinsed under f...
https://alphams.euen/analyses/#12 -
CORROSION TEST - HERBERT TEST - Cast Iron
Standardised iron filings are placed on a polished metal plate, over which a certain amount of the fluid to be analysed is poured. After a certain period, e.g. 24 hours, th...
https://alphams.euen/analyses/#13 -
CORROSION TEST Copper
A pre-polished copper strip is immersed in the fluid to be examined for a certain period and at a certain temperature. Afterwards the discolouration of the copper strip is ...
https://alphams.euen/analyses/#14 -
PARTICLE COUNT
The insoluble particles in the oil are counted to size and number using a laser sensor. The purity class is expressed in accordance with ISO 4406, NAS 1638 and/or SAE 4059J...
https://alphams.euen/analyses/#15 -
DENSITY
The density of the oil is expressed in kg/l. The density changes in relation to the temperature, increasing at a lower temperature. Checking the density of an oil provides ...
https://alphams.euen/analyses/#16 -
DEMULSIBILITY
The oil is mixed at a certain constant speed in the presence of an equal amount of water and at a temperature set in relation to the viscosity of the oil. After 5 minutes t...
https://alphams.euen/analyses/#17 -
DISPERSION ABILITY
The dispersion ability of an engine oil in use is measured using a CCD camera. Under standardised circumstances a stain is made with the engine oil. This stain is subsequen...
https://alphams.euen/analyses/#18 -
BREAKDOWN VOLTAGE
The breakdown voltage of an oil is measured by increasing the electric current between 2 electrodes placed at a set distance of each other in the oil. The breakdown voltage...
https://alphams.euen/analyses/#19 -
DRIP POINT
The lubricant to be measured is warmed up in a special cup in a dedicated container. The temperature at which the lubricant starts to drip is the drip point of the lubrican...
https://alphams.euen/analyses/#20 -
FALEX EP TEST
The oil is heated to a certain temperature in a metal container. In the container a small rod is mounted between 2 small metal cubes. The rod twists at a constant speed and...
https://alphams.euen/analyses/#21 -
FILTERABILITY
The oil to be measured is mixed with an aliquot of water and is filtered through a 0.8µm membrane filter under a pressure of 1 bar. The time it takes to filter 50 ml,...
https://alphams.euen/analyses/#22 -
GAS CHROMATOGRAPHY
By way of gas chromatography, the fuel content in the oil can be measured, but it is also possible to determine the antifreeze content.
https://alphams.euen/analyses/#23 -
FRACTIONAL DISTILLATION
By way of fractional distillation, substances with a different boiling point are separated from each other.
https://alphams.euen/analyses/#24 -
SULPHURISED ASH
The proportion of ash in an oil is determined by carbonisation at 775°C. The residue is treated with sulphuric acid, as a result of which the organometallic additives o...
https://alphams.euen/analyses/#25 -
GLYCOL (ANTIFREEZE) TEST
Any antifreeze present in the oil is detected by a chemical reaction, in which monoethylene glycol is converted into an aldehyde with a colour change as a consequence. This...
https://alphams.euen/analyses/#26 -
ICP SPECTROMETRY of a used oil - elements Zn, P, Ca, Mg, B, Si, Na, Fe, Cr, Mo, Al, Cu, Pb
The metal elements in the oil are measured through flame emission spectrophotometry. The oil is diluted with an organic solvent and then atomised with an inert gas into an ...
https://alphams.euen/analyses/#27